All Categories : EDA Tutorials Bookmark and Share

Title : MT-050: Op Amp Total Output Noise Calculations for Second-Order System
Company :
Date : 25-Mar-2009
Downloads : 30

Rate This File
5 Stars
4 Stars
3 Stars
2 Stars
1 Star

The total output noise for a single-pole system was analyzed in Tutorial MT-049. The circuit shown in Figure 1 below represents a second-order system, where capacitor C1 represents the source capacitance, stray capacitance on the inverting input, the input capacitance of the op amp, or any combination of these. C1 causes a breakpoint in the noise gain, and C2 is the capacitor that must be added to obtain stability.